Hygienic Pressure Measurement
Alfa Laval Pressure TransmittersApplication
The Alfa Laval pressure transmitter is designed to fulfil the demands of pressure measurement in sanitary and pharmaceutical production. It is suitable in filtration systems, pump systems, pressure vessels, valve matrixes etc.
Main features: - Long Term stability - High overload capacity - Good accuracy, 0.35 % of FS - 4-20 mA output (3 or 2 wire)
Standard range The Alfa Laval pressure transmitter range can be used with all media that are compatible with stainless steel W 1.4435 (AISI 316L). For usage with high media temperature a cooling element can be added thus media temperatures up to 300° C can be achieved. The flushable process connection is oil filled with FDA approved Oil and delivered in either Clamp DN 38 (ISO2852) / Clamp DN 40 (DIN32676) or Clamp DN 50 (ISO2852) / Clamp DN 51 (DIN32676). Optionally the Alfa Laval Pressure transmitter is suited for explosive area (zone 0 or 1).
Working principle The Alfa Laval pressure transmitter builds on a piezoresistive stainless steel sensor, which features small thermal effect and excellent linearity, making it possible to meet accuracy demands up to 0.1 % FSO (IEC 60770).
Technical data
Measuring ranges: -1 to 0 bar 0 to 1 bar 0 to 1.6 bar 0 to 2.5 bar 0 to 4 bar 0 to 6 bar 0 to 10 bar 0 to 16 bar 0 to 25 bar 0 to 40 bar
Accuracy Nominal pressure >0.4 bar : . . . . . . . .accuracy <=0.35%of FS Nominal Pressure <=0.4 bar: . . . . . . .accuracy <=0.5%of FS Nominal pressure >0.4 bar: . . . . . . . .accuracy <= 0.1 % of FS (option) Compensated temperature range: . . . .0 to 70 °C
Mechanical data Process connections: Clamp DN 38 (ISO2852)/Clamp DN 40 (DIN32676) Clamp DN 50 (ISO2852)/Clamp DN 51 (DIN32676) Flange DN40/PN40
Materials Wetted parts: . . . . . . . . . . . . . . . . .AISI 316 or hasteloy coated diaphragm (option) Casing: . . . . . . . . . . . . . . . . . . . . .AISI 304 Fieldhousing: . . . . . . . . . . . . . . . . . .AISI 303 (option)
Filling: . . . . . . . . . . . . . . . . . . . . . .FDA approved silicone oil
Operating temperature Wetted parts: . . . . . . . . . . . . . . . . .-25 to 125 °C (150 °C for . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 minutes with a max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ambient temperature of 50 °C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-25 to 300°C (with cooling tower option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Note: Except: TE67E111111130 (-1 to 0 barg): 0- 70 °C Ambient temperature: . . . . . . . . . . .-25 to 85 °C.
Operating temperature EX version (TE67Exxxxxxxx5) Wetted parts: . . . . . . . . . . . . . . . . .-25 to 125 °C Ambient temperature: Zone 0: . . . . . .-20 to 60 °C. Ambient temperature: Zone 1: . . . . . .-25 to 70 °C.
Protection Class M12 plug and fieldhousing: . . . . . . . . .IP67 Cable outlet: . . . . . . . . . . . . . . . . . .IP68/69K
Weight Pressure transmitter with diaphragm: . .min 500 gr.
Electrical data The electronics is as standard short circuit protected and equipped with reverse polarity protection. Power supply: . . . . . . . . . . . . . . . . .12-36 Vdc Power supply: . . . . . . . . . . . . . . . . .EX version . . . . . . . . . . . . . . . . . . . . . . . . . . . . (TE67Exxxxxxxx5): 14-28 Vdc
Output: . . . . . . . . . . . . . . . . . . . . .4-20mA, 2 wire or 3 wire Output EX version (TE67Exxxxxxxx5): . .4-20 mA, 2 wire Connection: . . . . . . . . . . . . . . . . . .cable outlet, M12 plug or cable gland M20 (only with fieldhousing option) Response time: . . . . . . . . . . . . . . . .<10 ms
Certificates - CE marked - 5 point calibration certificate (option) - 3.1 certificate (option) - FDA conformity declaration (option) - ATEX (option)
Electrical connections
Dimensions (mm)
|