The temperature transmitter that fits your sanitary process
Temperature Transmitter
Application
The Alfa Laval temperature transmitter is designed to fulfill the demands in Sanitary and pharmaceutical production
Main features are: Wetted parts in AISI316L, stainless steel Compact, and hygienic design (3A / FDA and EHEDG compliant) Measuring range: -20 to 150 °C Sensor element: PT100 sensor with 4 wire connection to transmitter Built-in transmitter with 4-20 mA output High accuracy
Standard range The Alfa Laval temperature transmitter features as standard a stainless steel field housing in excellent finish, suitable for sanitary applications. All process connections are as standard hygienic connections with high cleanability and bacteria tightness, as an option wetted parts can be electropolished down to Ra>0.4μ.
The design of the sensor tip ensures low response times and accurate measurements. The output can be supplied either as a standard 4...20 mA, 4...20 mA/HART® output or Profi bus® PA interface.
Working principle The Alfa Laval temperature transmitter relies on a fast response Pt100 sensor tip. The sensor element is as standard a DIN A sensor element which is connected with 4 wires to the build in transmitter. This ensures full resistance compensation and enables reliable and accurate measurements of process temperatures with a standard analogue output of 4-20 mA
Technical data Measuring ranges: 0 to 150°C -10 to 100 °C -20 to 150 °C
Resolution: . . . . . . . . . . . . . . . . . . .12 bit
Accuracy Pt 100 element: . . . . . . . . . . . . . . . .±(0.15+0.002 * t) [°C ] Transmitter accuracy input : . . . . . . . .0.1% of span Transmitter accuracy output : . . . . . . .0.1 °C
Mechanical data Process connections: Clamp DN 38 (ISO2852) / Clamp DN 40 (DIN32676) Clamp DN 50 (ISO2852) / Clamp DN 51 (DIN32676)
Sensor length: . . . . . . . . . . . . . . . . .from50mmto 300mm
Materials Wetted parts: . . . . . . . . . . . . . . . . .AISI 316 Fieldhouse: . . . . . . . . . . . . . . . . . . .AISI 304
Operating temperature Wetted parts: . . . . . . . . . . . . . . . . .-50 to 250°C Ambient temperature: . . . . . . . . . . . .-20 to 85 °C
Protection class : . . . . . . . . . . . . . . .IP 67 Maxmedia pressure: . . . . . . . . . . . . .16 bar
Weight sensor: . . . . . . . . . . . . . . . . . . . . . .approx 500 gr.
Certificates CE marked 3A (option) 3.1B certificate (option) Calibration certificate, 5 point calibration (option)
Electrical data The integrated 4 to 20 mA loop powered transmitter features as standard galvanic isolation between input and output.
Power supply: . . . . . . . . . . . . . . . . .6.5 to 36 Vdc Output: . . . . . . . . . . . . . . . . . . . . .4-20 mA, 2 wire Profibus DP 4-20 mA HART, 2 wire Connection: . . . . . . . . . . . . . . . . . .M12 plug or M16 cable gland
Response time (measured in water): Sensor tip ¸6mm . . . . . . . . . . . . . . .3.0 sec. Sensor tip ¸4mm . . . . . . . . . . . . . . .2.5 sec. Sensor tip ¸3mm . . . . . . . . . . . . . . .1.3 sec.
|