ATEX and IECEx certified (zone 1, 2, 21, 22) PROFINET interface module for directly interfacing up to four digital ATEX / IECEx load cells via PROFINET. The interface module type 4X70A can also be used in non-ATEX installations
ATEX EtherCAT Interface Module 4X60A
Type
Interface
Description
4X60A
EtherCAT
ATEX and IECEx certified (zone 1, 2, 21, 22) EtherCAT interface module for directly interfacing up to four digital ATEX / IECEx load cells via EtherCAT. The interface module type 4X60A can also be used in non-ATEX installations
ATEX Profibus DP Interface Module 4X35A
Type
Interface
Description
4X35A
Profibus DP
ATEX and IECEx certified (zone 1, 2, 21, 22) Profibus DP interface module for directly interfacing up to four digital ATEX / IECEx load cells via Profibus DP. The interface module type 4X35A can also be used in non-ATEX installations
ATEX Modbus TCP/IP Interface Module 4x50A
Type
Interface
Description
4x50A
Modbus TCP/IP
ATEX and IECEx certified (zone 1, 2, 21, 22) Modbus TCP/IP interface module for directly interfacing up to four digital ATEX / IECEx load cells. The interface module type 4X50A can also be used in non-ATEX installations
ATEX EtherNet/IP Interface Module 4X50A
Type
Interface
Description
4X50A
Modbus TCP/IP
ATEX and IECEx certified (zone 1, 2, 21, 22) Modbus TCP/IP interface module for directly interfacing up to four digital ATEX / IECEx load cells. The interface module type 4X50A can also be used in non-ATEX installations
Analog Output Module 4X79A
Type
Interface
Description
4X79A
Analog output (4-20mA or 0-10Vdc active output) and Ethernet interface
Analog output weighing module featuring a LED display, 4-20mA or 0-10Vdc active analog output and digital EtherNet interface. The module also features four I/O for level alarms and remote zeroing. This module can directly connect to up to four digital load cells, and can be used for ATEX / IECEx and non-ATEX installations.
ATEX Serial Interface Module 4X40A
Type
Interface
Description
4X40A
RS485
ATEX and IECEx certified (zone 1, 2, 21, 22) RS485 interface module for directly interfacing up to four digital ATEX / IECEx load cells via RS485. The interface module type 4X40A can also be used in non-ATEX installations
ATEX DeviceNet Interface Module 4X37A
Type
Interface
Description
4X37A
DeviceNet
ATEX and IECEx certified (zone 1, 2, 21, 22) DeviceNet interface module for directly interfacing up to four digital ATEX / IECEx load cells via DeviceNet. The interface module type 4X37A can also be used in non-ATEX installations
ATEX / IECEx Certified Power Supply 4051A
Type
Interface
Description
4051A
ATEX / IECEx power supply
ATEX and IECEx certified (zone 1, 2, 21, 22) power supply type 4051A used for supplying 4XXXA interface modules when used in ATEX / IECEx rated applications. The 4051A power supply and 4XXXA interface module must be installed in safe area i.e. outside the ATEX zone
Serial Interface Module 4140OEM
Type
Interface
Description
4140OEM
RS485
RS485 interface module for interfacing digital load cells to PLCs, PCs etc. The module is developed for OEM use and can be equipped with customized protocols
OEM Weighing Board 5008OEM
Type
Interface
Description
5008OEM
RS485, EtherNet, EtherCAT (pending)
OEM weighing board for interfacing up to 8 digital load cells to PLCs, PCs etc. This weighing board is developed for OEM use and can be equipped with customized protocols
Analog Output Module 4X29
Type
Interface
Description
4X29
Analog output (4-20mA or 0-10Vdc active output) and RS485 interface
Analog output weighing module featuring a small LED display, 4-20mA or 0-10Vdc active output and RS485 interface. The module also features four I/O for level alarms and remote zeroing. This module can directly connect to up to four digital ATEX load cells for use in non-ATEX installations
Load Cell Module MCE2010
Type
Interface
Description
MCE2010
Eilersen RS485 load cell bus
The load cell module type MCE2010 interfaces digital non-ATEX load cells to Eilersen weighing terminals and interface modules for communication to PLCs, PCs etc . The module MCE2010 replaces module MCE9610.
Analog Output Module MCE2029
Type
Interface
Description
MCE2029
Analog output (4-20mA or 0-10Vdc active output) and RS485 interface
Analog output weighing module featuring a small LED display, 4-20mA or 0-10Vdc active output and RS485 interface. The module also features four I/O for level alarms and remote zeroing. This module can be used for up to eight digital non-ATEX load cells. The module type MCE2029 can also be used in ATEX applications when connected to an ATEX 4X40A interface module
Profibus DP Interface Module MCE2035
Type
Interface
Description
MCE2035
Profibus DP
Profibus DP interface module for interfacing up to eight digital non-ATEX load cells via Profibus DP
PROFINET Interface Module 2070
Type
Interface
Description
2070
PROFINET
PROFINET interface module for interfacing up to eight digital non-ATEX load cells via PROFINET fieldbus interface
EtherNet/IP Interface Module 2050
Type
Interface
Description
2050
EtherNet/IP
EtherNet/IP interface module for interfacing up to eight digital non-ATEX load cells.
Serial Interface Module MCE2040
Type
Interface
Description
MCE2040
RS232/RS422/485
Serial interface module for interfacing up to eight digital non-ATEX load cells via RS232, RS485 or RS422.
Modbus ASCII/RTU Interface Module MCE2040
Type
Interface
Description
MCE2040
Modbus ASCII/RTU
Serial interface module for interfacing up to eight digital non-ATEX load cells via Modbus ASCII/RTU protocol
DeviceNet Interface Module MCE9637
Type
Interface
Description
MCE9637
DeviceNet
ODVA approved DeviceNet interface module for interfacing up to eight digital non-ATEX load cells via DeviceNet
Terminal Module MCE9601
Type
Interface
Description
MCE9601
24Vdc supply and Eilersen RS485 load cell bus
Connection between Eilersen RS485 load cell bus at one side and 24Vdc Power Supply and Eilersen digital weighing terminals on the other side