CIP CONTROLS, FLOW SENSORS
Flow monitoring in pipes from 1″ on of ultrapure aqueous media without particles like ultra-filtrated media
- Fully compensated measurement up to 100°C of highly pure media without particles, such as ultra-filtered media
- Material: 1.4435 incl. 3.1 material certificate
- Reliable dry-run protection and monitoring of pumps, filters or agitators
- Monitoring of filters or valves
- Response time < 5 s
- Long-life technology with integrated safety switch-off at temperatures > 100 °C
- Integrated self-protection: automatic turn off if T > 100 °C / 212°F
- Adjustable switching point
- 3A conform
- Process connection Tri-Clamp
| Technical Specification | |
| Process Connection | Tri-Clamp |
| Insertion length | Stainless steel 1.4435 (316L), Ra≤0.4 μm |
| Measuring range | 0,1…3 m/s |
| Accuracy | ±10% of the end value |
| Temperature range process | 0…100 °C |
| Temperature range CIP/SIP | 140 °C / max. 60 Min. |
| Operating pressure | max. 60 bar |
| Communication | PHP |
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information