POINT LEVEL SENSORS
Conductive multilevel detection even in non-metallic tanks
- Reliable full / empty detection of aqueous and conductive media in metallic pipes and vessels
- Multi-rod sensor with up to 4 electrodes
- Electrodes can be shortened as required
- Version with suspended rope electrodes available
Technical Specification | |
Process Connection | CLEANadapt G1″ | Adapter for Tri-Clamp, Varivent, APV, Dairy flange |
Insertion length | 200, 500, 850, 1000, 1500, 2000 mm (possible to shorten / bend rod) |
Wetted material | Stainless steel 1.4404 (316L) Ra≤0.8 μm | Plastic PP Hart | Coating PFA |
Measuring range | Minimum conductivity 1 μS/cm |
Available versions | Electrode coated / non-coated | Seilelektroden |
Temperature range process | 0…90 °C |
Operating pressure | max. 10 bar |
Communication | PNP |
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information